How-to

Why series LEDs drop motor voltage from 12 V to 8 V

Motors and motor starters Published 5 min read By Current Intel engineering team

Short answer

Each LED conducting in series with the motor holds its forward voltage, about 2 V, so two of them take 4 V from a 12 V supply and the motor sees 8 V. The fix is to move the LEDs into their own series-resistor branch across the motor terminals: 1 kohm at 1/4 W gives 10 mA, the motor receives the full supply, and the LEDs stay within their current rating.

On this page
  1. Where the four volts go
  2. The current problem hiding behind the voltage loss
  3. Move the LEDs to their own parallel branch
  4. Size the dropping resistor
  5. Verify the repair
  6. What not to do
  7. Questions asked

If your meter reads 8 V at a 12 V motor because two bipolar LEDs sit in the motor's current path, the circuit is doing exactly what physics demands: each conducting LED holds about 2 V of forward voltage, the pair takes 4 V, and the motor gets what is left. Raising the supply hides the fault and overstresses the LEDs. The correct fix is to take the LEDs out of the motor path and feed each one from its own resistor-limited branch across the motor terminals, which returns the full supply voltage to the motor and keeps the LEDs inside their current rating. This article shows where the volts go, how to rewire the branch, and how to size the resistor with the arithmetic in the open.

Where the four volts go #

Forward voltage is the voltage an LED holds across itself once it conducts. Over a wide current range it stays nearly constant, so an LED placed in series with a load behaves like a fixed voltage drop, not like a resistor. With two LEDs conducting in series with the motor, the motor terminal voltage is:

V_motor = V_supply − (Vf1 + Vf2) = 12 V − (2 V + 2 V) = 8 V

That matches the measured 8 V and the motor documentation's note that each series LED costs about 2 V. On a bipolar LED, only one of its two anti-parallel dies conducts at a time, so each LED contributes one forward-voltage drop regardless of which direction the motor runs.

The current problem hiding behind the voltage loss #

A small indicator LED is rated for roughly 20 mA continuous, while a motor draws whatever its load demands. In a series path, one of two things happens: the LED chokes the motor down to a trickle of current, or the motor current flows through the LED die and destroys it. The 8 V reading appears because the motor happened to be lightly loaded during the measurement. Load the motor and the LED current rises with it, and the stress gets worse. This is why the series arrangement is wrong even at the 8 V you measured.

Move the LEDs to their own parallel branch #

A bipolar LED across the motor terminals, in series with a resistor, shows direction on its own: the two dies conduct on opposite polarities, so the color flips when the DPDT switch reverses the motor. Rewire it as follows.

  1. Disconnect the supply and confirm the motor terminals read zero volts on your meter before touching any connection.
  2. Remove both LEDs from the series path and restore the direct switch-to-motor connection.
  3. Wire one bipolar LED in series with a dropping resistor, then connect that series pair directly across the two motor terminals. Connecting across the DPDT center terminals is electrically the same node.
  4. Give a second indicator location its own LED-plus-resistor branch across the same terminals. Never share one resistor between two LEDs.
  5. Restore power and run the motor in both directions.

The resistor is mandatory. With the motor no longer in series, nothing else limits the LED current, and a bare LED across the supply conducts until the die fails.

Size the dropping resistor #

The resistor absorbs the difference between the supply and the LED forward voltage at the current you choose:

R = (V_supply − Vf) / I

Worked example with this circuit's numbers: a 12 V fixed supply, a forward voltage of 2 V (an estimate derived from the measured drop; the LED datasheet value governs), and a target of 10 mA:

R = (12 V − 2 V) / 0.010 A = 10 V / 0.010 A = 1000 ohm

Resistor dissipation: P = I² × R = (0.010 A)² × 1000 ohm = 0.10 W, so a 1/4 W part runs cool with margin.

Target LED current Resistance Dissipation Practical choice
20 mA (rated maximum, no margin) 500 ohm 0.20 W Avoid
10 mA 1000 ohm 0.10 W 1 kohm, 1/4 W
5 mA (dimmer) 2000 ohm 0.05 W 2.2 kohm, 1/4 W

The decision: 1 kohm at 1/4 W, drawing 10 mA. Modern indicator LEDs are clearly visible at a few milliamps, and the source accepts reduced brightness. Read the actual forward voltage and maximum continuous current from the LED datasheet and recompute; if the supply were adjustable you would size for its highest output, but this one is fixed.

Verify the repair #

  1. Measure across the dropping resistor with the motor running. Divide that voltage by the resistance. For the chosen resistor, about 10 V across 1 kohm confirms 10 mA, below the LED rating; if the current is high, increase the resistance.
  2. Measure the motor terminals under load. Expect essentially the full supply, less only the normal sag of the supply and switch contacts, not the old 8 V.
  3. Throw the DPDT switch. The meter polarity reverses at the same magnitude, the motor reverses, and the LED shows its other color.
  4. Run loaded and unloaded in both directions. Speeds should match in each direction, and the resistor should be only warm, never hot.
  5. Briefly disconnect the LED branch. Motor-terminal voltage changes by a negligible amount, because the branch draws a few milliamps, confirming the LED no longer limits the motor.

What not to do #

Do not raise the supply to compensate; the motor regains its volts but the LEDs still carry full motor current and every added LED costs more voltage. Do not use series diodes or LEDs as speed droppers either; the drop depends on current and it steals the motor's breakaway torque. Motor inductance also throws a spike when the switch breaks contact mid-travel. The anti-parallel dies clip a spike to roughly one forward voltage, but only through the series resistor, so do not count the branch as a suppressor; if the contacts arc, fit a proper suppression device across the motor terminals.

Questions asked

What happens if a bipolar LED goes straight across the 12 V supply with no resistor?

Nothing limits the current except the supply and the LED die's small internal resistance, so it climbs far past the roughly 20 mA continuous rating and the die fails, usually open-circuit within seconds. A series resistor is not optional once the motor no longer drops the voltage for the LED.

Does raising the supply to 16 V fix the problem?

It restores the motor voltage, 16 V minus the 4 V the two LEDs hold, but the LEDs still carry the full motor current and remain overstressed, and every LED you add later drops the motor another 2 V. It masks the fault instead of removing it. Move the LEDs to a parallel resistor branch and keep the original supply.

Why does one bipolar LED indicate direction with only two leads?

A bipolar LED contains two dies wired anti-parallel: one conducts and lights when the polarity across it is one way, the other lights when it reverses. Across the motor terminals of a DPDT reversing circuit, the color therefore flips with rotation direction and no extra contacts are needed.

Can the LED branch double as a spike suppressor for the motor?

Not reliably. The anti-parallel dies do clip a switching spike to roughly one forward voltage, but only through the series resistor, which limits the clamping current. If the switch contacts arc or the supply resets on switching, add a proper suppression device across the motor terminals.

Do I need a second resistor for an indicator in a second location?

Yes. Every LED branch gets its own series resistor sized for the supply voltage, because each branch draws its own current from the same terminals. Two LEDs sharing one resistor would each see half the intended current when conducting alone and an unpredictable share otherwise.

Keep reading

  • How-to

    Reversing rotation on a star-delta starter: which two phases

    For a one-time direction change, exchange any two incoming phases at the dedicated supply termination ahead of the entire starter and leave every star and delta connection untouched: the rotating field follows the phase sequence, so the star start and the delta run reverse together. For forward and reverse in normal operation, add a mechanically and electrically interlocked reversing contactor pair upstream and close it before the star-delta sequence begins.

    Motors and motor starters

  • How-to

    Reconnecting a 12-lead 575 V delta motor to 480 V wye

    Reconnection follows the standard 12-lead map whether the winding is concentric or lap: jumpers 4-7, 5-8 and 6-9 come off, leads 4, 5, 6, 10, 11 and 12 tie into one star point, and pairs 1-7, 2-8 and 3-9 land on the lines. Series delta at 575 V puts 287.5 V on each group; parallel wye at 480 V puts 277 V, about 3.6 percent low. Make the move only when the nameplate lists the wye connection at the new voltage.

    Motors and motor starters

  • Explainer

    What a phase rotation tester tells you about motor direction

    A phase rotation tester fixes the order of the three supply phases at the points you connect, not the way a motor will turn. To predict direction before the first start, match that supply reading with a motor-rotation reading taken while the isolated shaft is turned in the required direction from a recorded viewing end, then land the leads in exactly that pairing. Any two conductors crossed anywhere downstream of the test point reverse the result.

    Motors and motor starters