Explainer
What M0, Mn, I0 and 60/100K mean on a servo motor nameplate
Short answer
M0 is the continuous standstill torque, Mn the continuous torque at rated speed, I0 the standstill current that goes with M0, and 60/100 K the two permitted winding temperature rises: 60 K stalled, 100 K turning. On the 1FT5 family the eleventh digit of the order number is the DC-link voltage code, and 0 there marks a winding intended for a 210 V DC link. Read every value on the plate from the documentation for that exact order number, never a neighbouring family's.

On this page
- What each marking stands for
- M0 and Mn: two duties, two currents
- I0: the current your drive must hold at zero speed
- What 60/100 K says about the winding
- The eleventh digit of the order number is the DC-link code
- Other markings that follow the same rule
- Turning 60/100 K into absolute winding limits at the reference ambient
- The decision for each case
- Questions asked
M0, Mn, I0 and 60/100 K on a servo motor nameplate are not decoration to guess at. M0 is the continuous standstill torque, Mn the continuous torque at rated speed, I0 the standstill current that goes with M0, and 60/100 K the two permitted winding temperature rises: 60 K stalled, 100 K turning. Those are the meanings. The values behind the symbols belong to one winding variant of one motor family, so you read them only from the documentation for the exact order number. On the Siemens 1FT5 family the order number itself carries a rating: the eleventh digit is the DC-link voltage code, and 0 there marks a winding intended for a 210 V DC link. Here is what each marking commits you to when you pair the motor with a drive.
What each marking stands for #
The plate compresses the motor into a handful of markings that must agree with each other and with the drive:
| Marking | Meaning | It pairs with |
|---|---|---|
| M0 | Continuous torque at standstill, in newton metres | I0 and the 60 K rise |
| Mn | Continuous torque at the plate's rated speed | The rated current In and the 100 K rise |
| I0 | RMS line current that produces M0 at zero speed, in amperes | The drive's continuous current rating |
| 60/100 K | Permitted winding temperature rise: 60 K stalled, 100 K rotating | The ambient, through the arithmetic further down |
| Eleventh digit of the order number | DC-link voltage code; 0 means 210 V on the 1FT5 family | The drive family's DC-link voltage |
M0 and Mn: two duties, two currents #
M0 is the torque the motor holds at zero speed, indefinitely, with the winding inside its standstill limit. Mn is the torque at the plate's rated speed, indefinitely. They are two thermal cases of one winding, not two ratings for the same job. Each carries its own current on the plate — I0 with M0, In with Mn — and the ratio between the two torques is a property of that winding variant, not something you derive. Read both.
The decision follows the duty. An axis that holds load at standstill, such as a vertical axis, a clamp or a holding mandrel, is sized on I0, because the drive's continuous current must cover the stall for as long as the axis holds; the drive's peak and overload figures cover acceleration transients, never a standing stall. For a duty that mostly spins, the check moves to the drive's continuous current at speed against In, with Mn as the torque check. That split is the servo version of the sizing question in VFD rated current vs motor full-load starting torque: continuous rating first, brief overload second.
I0: the current your drive must hold at zero speed #
I0 is the RMS line current that produces M0 at standstill. It is a line current, measured at the drive's output terminals phase by phase, not a winding-internal figure — the same distinction that governs any motor nameplate current is line current, not winding current reading. A permanent-magnet synchronous servo makes torque from controlled stator current, so I0 is literally the current your drive must regulate and hold at zero speed: check the drive's continuous current rating against it, and treat the peak rating as acceleration headroom. An axis that stalls against a hard stop or carries a vertical load runs at I0 continuously; the drive has to live there, not visit.
What 60/100 K says about the winding #
60/100 K is a winding statement in kelvin of temperature rise. It is neither a temperature nor an ambient rating, and it covers the two duties the plate already names: the lower figure, 60 K, applies at standstill under M0, where the motor's own ventilation is gone; the upper figure, 100 K, applies in rotating operation. IEC 60034-1, Rotating electrical machines — Part 1: Rating and performance, is the standard behind the arithmetic: it fixes the 40 °C reference ambient for rise ratings and assigns rise limits by insulation class, measured by resistance. The rotating figure sits at the resistance rise limit the standard assigns to class F insulation, so the pair reads as a class F winding run to its rotating limit and de-rated at standstill; take the class from the plate or the family data rather than from the coincidence.
The limits are defined on resistance-measured rises, so checking a hot motor means measuring winding resistance cold and hot at the terminal box. That box opens only de-energized: lock out the drive, let the DC-link capacitors discharge, and verify absence of voltage at the terminals first. Confirm the edition your authority having jurisdiction enforces and the motor's own documentation before relying on any figure here.
The eleventh digit of the order number is the DC-link code #
On the 1FT5 family, the eleventh digit of the order number is itself a rating: the DC-link voltage code. A 0 in that position marks a winding intended for a 210 V DC link. That is a link-side figure for the winding, not an AC supply rating — the motor never sees the line directly — and it is not a code that transfers to other digit positions or other families. 1FT5 and 1FT6 are different families with the same-looking symbols over different numbers, so a neighbouring family's catalog will decode your plate confidently and wrongly.
The pairing decision is physical. A drive fed from a 400 V three-phase line carries roughly 1.35 × 400 V ≈ 540 V on its link — a six-pulse estimate to check against the drive's own data — and a 210 V winding does not go across that. You read the code the way you read any voltage pairing on a plate, as in reading a dual voltage frequency spindle motor nameplate: the code resolves only against that exact winding's documentation. If the digit is unreadable or the document for your order number will not turn up — the 1FT5 family's operating instructions are published through the manufacturer's support portal — stop there and take the complete order number and a legible plate photo to that support channel before configuring anything.
Other markings that follow the same rule #
Servo plates carry more family-bound markings than these five. A feedback marking, for example a resolver's excitation frequency and voltage, decodes from the feedback device's own data the same way; what 5000 Hz and 7 V resolver markings on a spindle mean works through one such pair in detail. Insulation class, brake ratings and encoder part numbers obey the same rule: every value comes from the documentation for your order number, never from a plate that merely looks similar.
Turning 60/100 K into absolute winding limits at the reference ambient #
Inputs, each with its source:
- 60/100 K, the permitted winding rises from the nameplate; the family's documentation pairs the lower figure with standstill at M0 and the upper with rotation.
- 40 °C, the reference ambient for rise ratings, fixed by IEC 60034-1.
- Resistance method, the measurement basis the same standard defines for those rises.
Rule in words: absolute winding temperature limit equals reference ambient plus permitted rise. Adding kelvin to degrees Celsius is legitimate because a kelvin and a degree Celsius are the same interval.
Arithmetic:
- Standstill, holding M0: 40 °C + 60 K = 100 °C.
- Rotating at rated speed: that same reference ambient plus 100 K = 140 °C.
Result: the winding may reach 100 °C by resistance in a standing stall and 140 °C by resistance at rated speed, in an ambient at the value the standard assumes.
Decision: IEC 60034-1 trims the permitted rise by the amount the real ambient exceeds the reference ambient, so subtract the excess kelvin one for one. In a 55 °C cabinet the budgets become 100 °C - 55 °C = 45 K stalled and 140 °C - 55 °C = 85 K rotating. If your duty needs more than 85 K of rise to keep the axis turning in that cabinet, the winding is wrong for the spot: fit a winding whose documentation allows the duty, or bring the cabinet back below the reference ambient.
The decision for each case #
- Holding duty, such as a vertical axis, clamp or mandrel: size the drive's continuous current to I0; a peak rating never covers a standing stall.
- Spinning duty: drive continuous current at speed against In, torque against Mn.
- Winding temperature: 60 K of rise stalled, 100 K rotating, referenced to the standard's reference ambient; every kelvin of ambient above that costs one kelvin of rise.
- Drive pairing: read the eleventh digit — 0 on a 1FT5 order number is the 210 V DC-link winding — and land the motor only on a drive family whose link matches it, never across a link near 540 V.
- Unreadable digit or missing data: complete order number plus legible plate photo through the manufacturer's official support channel, before any configuration.
Questions asked
Can I decode a 1FT5 plate with a newer servo family's catalog?
No. Families that look alike print the same symbols over different numbers; even the voltage code sitting at the eleventh digit position moves between families, so a neighbouring catalog decodes your plate confidently and wrongly. Decode it with the catalog or operating instructions for your exact order number, and if that document will not turn up, send the complete order number and a legible plate photo through the manufacturer's official support channel before connecting anything.
Is the 210 V DC-link code the AC supply the motor needs?
No. It is the DC voltage the winding is built for, on the drive's link side, so it describes the drive generation that feeds the motor rather than the plant's AC line. The motor never sees the line directly: the drive's rectifier sets the link. Match the code against the drive family's DC-link voltage, and treat any AC-side question as a drive question.
Is M0 the holding torque of the motor's brake?
No. M0 is electromagnetic torque: it exists only while current flows, and it is what the drive uses for powered holding at standstill. The brake is a separate mechanical device with its own torque rating, holding the axis with current off, normally as a stop-and-hold measure rather than a positioning one. Size powered holding with M0 and I0; take the brake's figure from the brake's own data.
How fast does insulation age if the 60/100 K limits are exceeded?
Thermal aging follows the rule of thumb that every 10 K of sustained extra temperature roughly halves the insulation's service life. A winding held 20 K beyond its standstill limit through a long holding duty therefore ages about four times faster than designed. Short excursions matter far less than a standing overshoot, which is why continuous stall duties deserve the 60 K check, not the rotating one.
How do I measure the winding temperature to compare with 60/100 K?
Use the resistance method the rise limits are defined on: record the cold winding resistance and its temperature, run the duty in question, then lock out, verify absence of voltage, and measure the hot resistance at the terminal box before converting it with the copper constant the method's description gives. The result is the average winding temperature by resistance, the same basis as the two plate figures.