Selection guide
Sizing a VFD retrofit motor for a lathe spindle
Short answer
A 5 hp (3.73 kW) four-pole inverter-duty motor on a sensorless-vector VFD replaces the reported 7.5 hp brushed DC spindle motor on a lathe with one fixed belt ratio: it holds 20.4 N·m continuously against the original's 21.0 N·m, which is the torque the single ratio forces the motor to make. Top speed falls to about 3500 against 6500 min⁻¹. Size the drive to the motor's nameplate current.

On this page
A 5 hp (3.73 kW) four-pole inverter-duty motor on a sensorless-vector VFD replaces this lathe's reported 7.5 hp brushed DC spindle motor, provided the motor's documentation permits 120 Hz operation and the drive's heavy-duty current rating covers the motor's nameplate amps. The deciding number is shaft torque, not the horsepower label. The old plate works out to 21.0 N·m where low-speed cutting happens; the replacement makes 20.4 N·m and holds it across its constant-torque range. With one fixed belt ratio and no back gear, that is the number the spindle feels. The trade is top speed: about 3500 against the original's 6500 min⁻¹.
What the old plate really says #
The machine is a small CNC turning center: 6 in chuck, 11 in swing over the bed, 6 in over the cross slide, and a belt-drive spindle with a single ratio and no back gear. Its spindle motor is a brushed DC machine. The plate reads 400 V 15 A for the armature, a speed range of 2500–6500 min⁻¹, and a power marking that reads 5-5 kW. A separate excitation range, 310–86 V at 1.05–3 A, belongs to the field winding.
That field winding explains the speed range. A DC spindle drive holds constant torque below base speed by raising armature voltage, then cuts field current to hold constant power above it, so 2500 min⁻¹ is the base speed and everything above it is the constant-power band.
Read the power marking as 5.5 kW: the machine is described as carrying a 7.5 hp spindle, and 7.5 hp × 0.746 kW per hp = 5.6 kW, which matches the plate only as 5.5 kW, so confirm it on the physical plate before ordering anything. The controller was regenerative and integrated with the machine control. The machine's own plate, 3×380/220 V, 60 Hz, 16 A, rates the whole machine at about 10.5 kVA at 380 V, not the spindle; what a machine kVA nameplate means for VFD sizing covers that reading. Coolant pump and lights run on 220 V, 60 Hz.
The motor plate also cites VDE 0530, the German rotating-machine standard since aligned with the IEC 60034 series, with insulation class F, a 155 °C winding temperature class, and IP 23, an open construction. A brushed DC machine cannot take a VFD's PWM output, so the retrofit replaces motor and drive together.
Torque sizes this spindle, not the horsepower #
With a back gear or a multi-speed motor the drivetrain multiplies torque; here one belt ratio only passes the motor's torque through, so the candidates compare directly on rated shaft torque. The problem in replacing a three-speed lathe motor with a VFD differs for exactly that reason. Drive-engineering references define the constant-torque range as the speed band in which the motor delivers full torque continuously, limited by its own cooling.
The conversion is T = 9549 × P / n, with P in kW and n in min⁻¹; the constant is 60 × 1000 / 2π. For the original at base speed: 9549 × 5.5 / 2500 = 21.0 N·m, held from zero up to base speed. Above it, power stays flat and torque falls to 9549 × 5.5 / 6500 = 8.1 N·m at the top of the range.
A 5 hp motor is 5 × 0.746 = 3.73 kW. A four-pole turns at about 1750 min⁻¹ at full load on 60 Hz, so its rated torque is 9549 × 3.73 / 1750 = 20.4 N·m, within 3% of the original, and a sensorless-vector drive holds it from a few hertz to base speed. Sanity check on the formula: a 1.5 hp four-pole at 1450 min⁻¹ gives 7.4 N·m, matching the shop figure of about 7.3 N·m.
Power margin then follows from the duty. A working shop estimate for steel is about 1 hp per cubic inch removed per minute, so 0.5 in³/min costs roughly 0.5 hp at the spindle, and a non-production 6 in chuck lathe sits far below what 5 hp sustains. Rigidity, not the motor, limits the cut.
The candidates, compared #
| Candidate | Power | Rated torque | Constant-torque band | Constant power up to | Verdict for this lathe |
|---|---|---|---|---|---|
| Original brushed DC | 5.5 kW | 21.0 N·m at 2500 min⁻¹ | 0 to base speed | 6500 min⁻¹ | The reference; needs its 380 V regenerative controller |
| 5 hp four-pole | 3.73 kW | 20.4 N·m | a few Hz to base speed | twice base speed | Choose it: torque parity where cutting happens |
| 7.5 hp four-pole | 5.6 kW | 30.5 N·m | a few Hz to base speed | twice base speed | Only if production cuts must hold full power at high spindle speed |
| 3 hp four-pole | 2.24 kW | 12.2 N·m | a few Hz to base speed | twice base speed | No: 42% short of the original's low-speed torque |
Candidate torques are rated at the four-pole base speed, about 1750 min⁻¹; twice base speed means the motor documentation permits 120 Hz, which is about 3500 min⁻¹. Top speed is set by pole count, the documented overspeed limit and the pulley ratio, and a bigger four-pole does not raise it.
The belt ratio in numbers #
Example inputs, to be replaced with your own measurements: a pulley ratio of 2.0:1 motor-to-spindle, and one V-belt stage at 96%, an estimate.
Spindle torque, original: 21.0 × 2.0 × 0.96 = 40.3 N·m up to 1250 min⁻¹ at the spindle, then 5.5 kW × 0.96 = 5.3 kW up to 3250 min⁻¹.
Spindle torque, replacement: 20.4 × 2.0 × 0.96 = 39.1 N·m up to 875 min⁻¹, then 3.73 kW × 0.96 = 3.6 kW up to 1750 min⁻¹.
Where facing and roughing happen, the two are a wash. The loss is the upper band: between 875 and 1250 min⁻¹ the replacement is already in constant power while the original still held full torque, and the top of the spindle range falls by nearly half. Check that against your smallest finished diameter: surface speed is v = π × D × n / 1000 in m/min with D in mm, so a 13 mm bar at 1750 min⁻¹ sees π × 13 × 1750 / 1000 = 71 m/min, against 133 m/min on the original. If small-diameter finishing matters to you, fit a pulley pair that puts the motor's top speed where you need it; with the original pulleys in place, accept the lower ceiling.
The drive and the supply #
Size the drive from the motor's nameplate full-load current, with the drive's heavy-duty rating at or above it; how VFD rated current relates to motor starting torque goes through why a drive needs no starting margin. Set the control mode to sensorless vector and the load type to constant torque, in the drive's motor-data settings.
The old controller returned braking energy to the line. Give the VFD a braking chopper and resistor for controlled stops, or lengthen the deceleration ramp until the DC bus stays down. Chuck and workpiece inertia set the acceleration ramp too: the motor starting time calculation with torque margin and inertia shows the arithmetic.
On supply, the shop already has 220 V three-phase, and the auxiliaries stay on their own 220 V, 60 Hz circuits, never on the drive output. Pick a 230 V-class drive and a dual-voltage motor connected for 230 V; reading a dual voltage frequency spindle motor nameplate shows which terminals that selects. If the supply is single-phase only, size the drive by how to size a VFD for a three-phase motor on single-phase input.
Before tracing the old spindle-power path or disconnecting the DC controller, de-energize the machine, lock it out, and test for absence of voltage at the terminals you will open; in the United States, NFPA 70E, 2024 edition, is the standard covering that verification. The 380 V spindle circuit and the 220 V auxiliaries are separate sources until the wiring proves otherwise.
Prove it on the machine #
Before the first cut, verify rotation, compare commanded with measured spindle speed using a tachometer across the range, and read motor current per phase during a heavy pass; it must stay at or below nameplate full-load current. A drive that trips only in the cut is a different fault, and why a spindle VFD trips motor overload only during cutting walks through it. Watch winding temperature against the class F limit, set the drive's electronic thermal protection from the nameplate amps, then step the cuts up progressively and confirm the stop you programmed.
Questions asked
Can the brushed DC motor stay if I fit a modern DC drive instead?
Yes, that is the alternative to the AC retrofit. A modern four-quadrant DC converter runs a brushed spindle motor and returns braking energy the way the original controller did, but it must match the armature rating of 400 V 15 A and the field range of 310 to 86 V, and the supply problem remains: the spindle still wants its 380 V three-phase while the auxiliaries run on 220 V. That is why most such retrofits replace motor and drive together and move the spindle onto the voltage already in the shop.
Does the retrofit affect thread cutting on the CNC control?
Only through feedback. Synchronized thread cutting needs the control to know spindle position, and a VFD-driven motor does not provide that by itself. Keep the machine's existing spindle sensor working, or fit an encoder on the spindle rather than on the motor, so the pulses per revolution stay independent of the belt ratio. The motor and drive choice does not change that requirement.
Why would the drive trip on overvoltage when the spindle stops?
Deceleration turns the inertia of chuck and workpiece into energy, and that energy charges the drive's DC bus. Without a braking chopper and resistor it has nowhere to go, so the bus climbs until the drive trips or abandons the ramp and coasts. The original regenerative controller fed that energy back into the line. Fit the chopper and resistor, or set a deceleration time long enough that the bus stays within limits.
Does the retrofit motor need its own cooling fan?
For sustained full-torque cuts at low speed, yes. A shaft-mounted fan moves almost no air below about 15 Hz, so a self-cooled motor overheats if it holds rated torque there for long. Pick an inverter-duty motor with a constant-speed auxiliary blower, or keep heavy low-speed passes short and watch winding temperature. Short hobby cuts with pauses between them are the forgiving case.