What the generalized phase converter numbering scheme means
Short answer
The first digit of the generalized phase converter code is 1 only when an A-B starting capacitor and its switching means exist; the second counts running branches (0 none, 1 A-B, 2 A-B and C-B, 3 those plus A-C power-factor correction); the letter is N when the manufactured phase stays inside the equipment and B when it feeds external loads. The code describes connections, never capacity or balance.
On this page
- What do the two digits and the letter in a phase converter code mean?
- How do you assign a code from the wiring in front of you?
- Why is a plain three-phase motor coded 00B?
- Which code does a self-starting motor on a single-phase line get?
- Which codes cover static phase converters?
- Which codes cover rotary phase converters?
- What makes a Type 11 machine reverse almost instantly?
- How do several idlers on one bus fit the scheme?
- What does the code not tell you?
- Questions asked
The generalized phase converter scheme compresses any single-phase-to-three-phase circuit into two digits and a letter: the first digit records whether a starting capacitor branch with its switching means exists, the second counts the running capacitor branches, and the letter says whether the manufactured phase leaves the equipment. That is the entire classification. This article decodes each position, assigns codes to the arrangements you meet in the field — a plain three-phase motor, a self-starting motor on a single-phase line, a static converter, a rotary converter, a multi-idler bank — and works one capacitance example with the arithmetic shown, so you can label a panel from its drawing and know what the label does and does not promise.
What do the two digits and the letter in a phase converter code mean? #
The first digit is 1 only when the circuit has an A-B starting capacitor and its starting means, the second digit counts running capacitor branches, and the letter is N when the manufactured phase stays inside the utilization equipment or B when it is propagated outside it.
A and C name the two single-phase supply conductors; B names the manufactured third leg that the capacitor network creates. The starting means is usually a potential relay that disconnects the start branch as the motor approaches full speed. The second digit reads 0 for no running branch, 1 for a single A-B branch, 2 for A-B and C-B branches together, and 3 for those two plus an A-C branch across the supply lines that corrects the power factor the single-phase service sees. The code counts functional branches rather than individual cans, and the letter tracks only where conductor B ends, so it cannot tell you which way power flows or whether the shaft is loaded.
How do you assign a code from the wiring in front of you? #
Trace three things in order — a switched A-B branch with its relay or contactor for the first digit, the unswitched capacitor branches for the second, and where conductor B ends for the letter — and the code falls out of any drawing in a few minutes.
Before anything is opened, make the panel electrically safe: NFPA 70E, the 2024 edition, covers the de-energize, lockout and absence-of-voltage verification steps, and the details that bind your job come from your authority having jurisdiction and the machine's documentation. Begin at the line side: identify the two supply conductors, call them A and C, and mark the third leg B wherever a capacitor or the motor creates it. Look for a capacitor in series with a relay or contactor across A and B — that assembly, capacitor plus starting means, is the entire first digit. Count the unswitched running branches by their conductor pairs. Follow B last: if it stops at the machine's own terminal box, write N; if it runs on to a bus, a second motor or any other load, write B.
| Code | Type | Starting branch | Running branches | B outside? |
|---|---|---|---|---|
| 00N | 0 | no | none | no |
| 01N | 1 | no | A-B | no |
| 02N | 2 | no | A-B, C-B | no |
| 03N | 3 | no | A-B, C-B, A-C | no |
| 00B | 4 | no | none | yes |
| 01B | 5 | no | A-B | yes |
| 02B | 6 | no | A-B, C-B | yes |
| 03B | 7 | no | A-B, C-B, A-C | yes |
| 10N | 8 | yes | none | no |
| 11N | 9 | yes | A-B | no |
| 12N | 10 | yes | A-B, C-B | no |
| 13N | 11 | yes | A-B, C-B, A-C | no |
| 10B | 12 | yes | none | yes |
| 11B | 13 | yes | A-B | yes |
| 12B | 14 | yes | A-B, C-B | yes |
| 13B | 15 | yes | A-B, C-B, A-C | yes |
The Type numbers follow one pattern worth memorizing: Types 0 through 3 have no starting branch and keep B inside, with the running-branch count equal to the type number; Types 4 through 7 are those same circuits with B taken outside; Types 8 through 11 add the starting branch with B inside; Types 12 through 15 add it with B outside.
Why is a plain three-phase motor coded 00B? #
A three-phase motor fed normally from a three-phase source has no starting capacitor and no running branches, yet its third conductor is live at the terminal box and available to external equipment, so the code reads 0, 0, B — Type 4 in the revised numbering.
The letter was defined at the connection level, so it cannot distinguish a driven motor from a driving converter. The same 00B covers the oldest rotary converter on the floor: an idler with no capacitors at all, brought up to speed by a pony motor, then paralleled with the single-phase lines so it generates the third leg for the whole bus. Neither shaft load nor power-flow direction moves the designation, which is why a pony-started unit and a building full of conventionally fed motors share one code.
Which code does a self-starting motor on a single-phase line get? #
A three-phase motor started from a single-phase line by one running capacitor, with the manufactured phase used only by the motor itself, is 01N — Type 1 — and that A-B branch is sized about 30 to 35 µF per horsepower for integral-horsepower motors and about 50 µF/HP for fractional horsepower.
Because the motor is the only load, conductor B never leaves the terminal box and the letter is N; this is the arrangement behind running a three-phase motor on single-phase 208 V. The single capacitor supplies both the starting torque and the running balance, which keeps the circuit simple but leaves little margin: a heavy or high-inertia load may simply refuse to accelerate, and the motor design and shaft load decide that, not the code.
Worked example, with every input stated: the motor is 5 hp, three-phase, 230 V, 60 Hz, squirrel-cage, self-started on a single-phase 230 V supply as a Type 1 circuit, with the branch sitting across the A-B pair at the supply voltage. The rule of thumb above spans 5 hp × 30 µF/hp = 150 µF to 5 hp × 35 µF/hp = 175 µF, so a standard 165 µF capacitor lands mid-range. Its current follows the capacitive impedance relation I = 2πfCV: 2π × 60 Hz × 0.000165 F × 230 V ≈ 14.3 A, flowing continuously for as long as the motor runs, which is why the branch conductor and the capacitor must be rated for that current without a time limit. Treat the capacitance as an estimate to be checked against the motor documentation and confirmed by measuring the three line currents and the three line-to-line voltages under load; the right value moves with motor design and shaft load.
Which codes cover static phase converters? #
A static converter has a starting branch and no rotating idler of its own, so its code begins with 1 and ends with N: the plain unit with a switched starting capacitor alone is 10N (Type 8), and the heavy-duty unit that adds an A-B running capacitor is 11N (Type 9).
Both keep B inside because the only three-phase machine is the motor being run. The static converter borrows the motor's own windings to form the third leg: the start branch kicks the rotor moving, the relay drops it out, and the motor then runs on single phase at reduced usable output. Adding the A-B running branch in an 11N improves the balance at the operating point, but the capacitance is easy to overshoot, and an oversized branch overheats the very motor it was meant to help — why more run capacitance overheats a static converter motor is that failure mode worked through in detail.
Which codes cover rotary phase converters? #
A rotary converter is any unit whose manufactured phase feeds equipment beyond its own terminals, so every code with the letter B applies — from a capacitor-free, pony-started idler at 00B (Type 4) to a fully equipped 13B (Type 15) with two balancing branches and input power-factor correction.
The self-starting ladder runs 01B, then 10B, 11B, 12B and 13B — one running branch, or a starting branch alone, or a starting branch plus one, two or three running functions. Each added branch does a distinct job: a second balancing branch pulls the manufactured-leg voltage toward the other two, and the A-C branch corrects the power factor the single-phase service sees. The improvements are modular — why a rotary phase converter needs three capacitor banks explains how those run branches share the balancing work — so a shop that begins at 00B or 10B can climb toward 03B or 13B bank by bank without touching its starting means.
What makes a Type 11 machine reverse almost instantly? #
Type 11, code 13N, is a self-starting machine fed from a single-phase line whose A-B and C-B running branches are built with equal capacitance so it runs equally well in either direction, and on a machine with a spindle brake that symmetry allows near-instant reversal.
The equal values exist because the machine must be bidirectional: no supply leg is privileged, so either one can pair with the manufactured leg. Direction is still switched by contactors — why reversing a three-phase motor needs two contactors covers the interlock that a reversing feed requires, single-phase-derived or not. The mechanical brake is what buys the speed: the control stops the spindle, drops the contactors into the other order and re-accelerates from near standstill, which is why toolroom lathes wired this way reverse from single-phase power almost as briskly as three-phase-fed machines do.
How do several idlers on one bus fit the scheme? #
Only one unit in a multi-idler bank needs a starting branch, because once the first idler is up its manufactured phase supplies the rest, and each converter still carries its own code for the elements it actually contains.
Classification follows potential, not the job of the moment. A secondary idler's voltage-sensitive starting means sees a healthy manufactured-phase voltage on the bus and stays open; if the primary unit trips offline, the bus voltage collapses, the secondary's starter picks up, and that machine becomes the primary without anyone changing a label. A unit coded 11B can therefore sit for years with its start branch never energized while a healthier neighbor does the starting. A drive-fed idler removes the question entirely: starting a rotary phase converter idler from a VFD ramps the machine up from zero frequency, so no starting branch ever enters its code.
What does the code not tell you? #
The code describes circuit topology only — it says nothing about horsepower capacity, voltage balance, starting torque or duty cycle, so a Type 15 converter can still be undersized for its load and a Type 1 motor can still stall on a hard start.
Converter makers publish load-difficulty classes such as easy, medium, hard and very hard precisely because two motors with the same nameplate horsepower present very different starting duty; the code has no field for any of that. Balance is a measurement, not a designation: read the three line-to-line voltages and the three motor currents under load before you accept a branch count as balanced. Component choice follows duty class rather than the code — the starting branch uses an intermittent-duty electrolytic capacitor connected only during acceleration, while running branches use oil-filled capacitors rated for continuous AC service at the branch voltage — so specify replacements from the documented capacitance, voltage and AC duty rating, not from the label on the panel door.
Questions asked
Is the two-digit-and-letter code defined by a standard?
No. IEC, IEEE, NEMA and UL documents do not define this designation; it is a descriptive convention for comparing single-phase-to-three-phase circuits, so you will meet it in shop notes rather than on a nameplate or a listing document. Treat the circuit diagram as the authoritative record of what is actually wired, and re-derive the code from that drawing whenever the label and the hardware disagree.
Does an unloaded motor such as a synchronous condenser change its code?
No. The scheme ignores shaft load entirely, so a synchronous motor spinning unloaded on a three-phase bus — a synchronous condenser, a source or sink of reactive vars — is the plain 00B case, and the same machine driving a load keeps the same code. Only the starting branch, the running branches and the boundary of conductor B can move a designation.
Does adding a capacitor later change a converter's code?
Yes, and the scheme is built for it. Wiring a C-B running branch into an 01B idler makes it 02B; adding an A-C power-factor branch to a 12B makes it 13B. Re-derive the designation from the as-built drawing after every modification, because a stale code sends the next technician looking for a branch that no longer exists.
Can I read the capacitance values straight from the code?
No. The second digit counts branches, not microfarads. Values follow the motor's size and design, then get trimmed against the line-to-line voltages and line currents measured under load; the per-horsepower figures quoted for a single-branch Type 1 are starting points for that one arrangement alone. Two converters with identical codes can carry different capacitance and both be right for their own motors.